新42b31573-fc38-475d-8c1f-a897f6593f1d.jpg

EX1KVA-3KVA Online UPS High Frequency UPS

EX1-3K series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.

Downloads:

  • Features
  • Specifications
  • Download
    • Commodity name: EX1KVA-3KVA Online UPS High Frequency UPS
    • Commodity ID: 1037782463234793472

    EX1-3K series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.

    Application

    EX1-3K series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.

    Features:

    ♦ Large Blue Ground LCD digital display shows Detail Real-Time UPS Status and parameters.

    ♦ Set output voltage, Frequency parameter and Bypass function on the display.

    ♦ Advanced MCU microprocessor control Technology, ensure long life reliability.

    ♦ Excellent Protection against over voltage, overload, over current, overcharge and so on.

    ♦ Input L and N lines reverse wiring detection.

    ♦ DC start function, input PFC revises function.

    ♦ Humanized bypass output adjustable.

    ♦ RS232 intelligent communication monitoring.

    ♦ AS-400 Dry contact and SNMP card remote intelligent control.

    ♦ Strong anti-jamming capability.

    ♦ Available to work with generators.

    ♦ Lightning, surge, short-circuit, network/fax/modem surge protection.

     

  •  Model

    EX1K

    EX1KL

    EX2K

    EX2KL

    EX3K

    EX3KL

    Capacity

    VA/W

    1000VA/800W

    1000VA/80W

    2000VA/1600W

    2000VA/1600W

    3000VA/2400W

    3000VA/2400W

    Input

    Nominal Voltage

    110/115/120VAC or 200/220/230/240VAC

    Voltage Range

    60~138VAC or 115~300VAC

    Frequency Range

    50Hz : 46~54Hz : 60Hz; 56~64Hz

    Phase

    Single phase with Ground

    Power Factor

    ≥0.97

    Output

    Voltage

    110/115/120 (1±2%) VAC or 208/220/230/240 (1±2%) VAC

    Frequency

    50/60Hz (Adjustable);  
    50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)
    60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)

    Wave Form

    Pure sine wave

    Power Factor

    0.8

    Harmonic Distortion

    ≤3% THD (Linear load); ≤7% THD (Non-linear load)

    Overload Capacity

    110%~150% maintain 30s then turn to bypass output, over 150% maintain 200ms

    Current Crest Ratio

    3:1

    Connections

    IEC320*4

    IEC320*4

    IEC320*6

     IEC320*3 & Terminal block

    IEC320*6

    IEC320*3 & Terminal block

    Efficiency

    TO Battery Mode

    83%

    TO AC Mode

    85%

    Battery

    Type

    Sealed free maintenance lead acid battery

    Nominal DC voltage

    Built in batteries 12V 7.0AH

    36Vdc

    Built in batteries 12V 7.0AH

    96Vdc

    Built in batteries 12V 7.0AH

    96Vdc

    Quantity 

    3 PCS

    Depend on requested back-up time

    8 PCS

    Depend on requested back-up time

    8 PCS

    Depend on requested back-up time

    Back-up Time (Full Load)

    ≥7min

    Depends on the capacity of external battery bank

    ≥7min

    Depends on the capacity of external battery bank

    ≥6min

    Depends on the capacity of external battery bank

    Recharge Time

    5 hours to 90% of capacity full discharge

    Depends on the capacity of external battery bank

    5 hours to 90% of capacity full discharge

    Depends on the capacity of external battery bank

    5 hours to 90% of capacity full discharge

    Depends on the capacity of external battery bank

    Charge Current (MAX)

    1.0 A

    5.0A/ 8.0A

    1.0 A

    1.0 A

    5.0A/ 7.0A

    5.0A/ 8.0A

    Charge Voltage (VDC)

    41.1V±0.4V

    41.1V±0.4V

    110V±0.6V

    110V±0.6V

    110V±0.6V

    110V±0.6V

    Bypass

    Automatic Transfer

    On overload and UPS failure

    Before UPS Power-on

    Default ”ON” user adjustable to “YES”

    Transfer Time

     

    0ms; less than 4ms from inverter to bypass and vice versa

    Indicators

    LCD Display

    UPS status, Battery capacity, loading, Fault code  (LCD: I/P&O/P voltage&frequency, Battery voltage)

    Audible Alarm

     

    Bypass, battery mode, Battery low, Overload, Fault

    Acoustic Noise

    At 1 Meter Distance

    <45dB

    <50dB

    Communications

    Intelligent RS232 serial port

    Software support Windows family software, Linux, Sun network operating system,IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC

    SNMP (Optional)

    Remote control UPS through SNMP management and Internet

    USB (Optional)

    Windows family software and Mac OS

    Network Surge Protection

     

    RJ45 I/O port available for network or FAX/Telephone line/Modem

    Environmental

    Operating Temperature

    0~40℃

    Operating Humidity

    20-90% (No condensing )

    Weight

    Net Weight (kgs)

    11

    5.5

    26.5

    10.5

    27

    11

    UPS Dimension

    L*W*H (mm)

    370*145*220