GS Series 4-6kw Hybrid Solar Inverter
Features:
GS Series AC/Solar charging Off grid Hybrid lnverter.
LED/LCD display,Enhanced functions setting via LCD,Man-machine intelligent design.
Built-in 40A/60A optional MPPT solar charger controller.
LCD shows the solar capacity.
5 stages adjustable AC charging current. AC charging also can be closed.
AC/DC priority modes can be closed.
Generator restart signal(Dry contact).
3 times peak power.Strong loading capacity.
Overload,output short-circuit protection.
Specifications:
Model |
GS4000 |
GS5000 | GS6000 | |
Power Rating | 4000W | 5000W | 6000W | |
AC Input |
Input Voltage Waveform |
Sinusoidal(utility or generator) | ||
Nominal input Voltage |
120/230VAC | |||
Low Line Disconnect |
85Vac±4%(Normal) or 80Vac±4%(Wide) for 120Vac 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230Vac | |||
Low Line Re-connect |
95Vac±4%(Normal) or 85Vac±4% (Wide) for 120Vac 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230Vac | |||
High Line Disconnect |
136Vac±4%(Normal) or 145Vac±4%(Wide) for 120Vac 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230Vac | |||
Max AC input Voltage |
120Vac for Max150Vac, 230Vac for Max270Vac | |||
Frequency | 50Hz:41-54Hz,60Hz:51-64Hz | |||
AC Charger |
Nominal Charge Current |
20A/35A/50A/70A/90A(5 stages adjustable charging current) | ||
Over Charge Protection |
Bat.V>15.5VDCfor 12V battery ; Bat.V>31.0VDC for 24V battery, Bat.VN62.0VDC for 48V battery ; beeps 0.5s every 1s & fault after 60s | |||
Solar Charger |
Rated Charge Current |
60A | 60A | 60A |
PV Input Voltage range |
12VDC. 25VDC-75VDC for 24VDC. 55-145VDC for 48V | |||
Max.PV open circuit array voltage |
12V for40VDC, 24V for 75VDC, 48V for 145VDC | |||
Charger mode | MPPT | |||
PV Low Voltage Re-connect |
PV>Bat.V=3V | |||
PV Low Voltage Disconnect |
PVWBat.V | |||
Efficiency | >97% | |||
Charger |
Nominal Charger Current |
20A/35A/50A/70A/90A(According to the inverter model), 5 stages adjustable charging current | ||
Over charge Protection |
Bat.V>15.5VDC/31VDC/62VDC,beeps 0.5s every 1s & fault after 60s | |||
Efficiency |
Efficiency (Battery Mode ) |
>87% | ||
Efficiency (Line Mode) |
>98% | |||
Battery Voltage |
Nominal DC Input Voltage |
24/48VDC | ||
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC, 21VDC±0.6VDC for 24VDC, 42VDC±1.2VDC for48VDC | |||
Low DC input shut-down |
20VDC±0.6VDC for 24VDC, 40VDC±1.2VDC for48VDC | |||
High DC input Alarm & Fault |
32VDC±0.6VDC for 24VDC, 64VDC±1.2VDC for48VDC | |||
Transfer Time | AC to DC DC to AC | 20ms(max) 15ms(max) | ||
System Parameter | Over-Load Protection | 110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, load>150%, beeps 0.5s every 1 s, and Fault after 20s | ||
Output Short Circuit Protection | Current limit(Fault after 10s) | |||
Surge Rating (10s) |
1:3(VA) | |||
Power Saver | Load<25W(Enabled on "P/S auto"Setting of Remote control) | |||
Protections | Low battery.over charging,over load,over temp | |||
Indicators | LED+LCD Display | |||
General Specification | Operating Temperature Range | 0°C to 40°C | ||
Storage Temperature | -15°C 〜60°C | |||
Operation humidity | 5% to 95%(non-condensing) | |||
Audible Noise | 60dB max | |||
cooling | Forced air,variable speed fan | |||
Dimension(L*W*H) | 530*400*190mm | |||
Net Weight(kg) | 30kg | 35.5kg | 39.0kg |
Related products
Subscribe
Check the latest news of our company anytime and anywhere.
Explanation of Enquiry
Contact ZLPOWER
Fax: +86-755-27649950 Ext830
Floor 1- 3, Building 2, Runteng Shangpai Industry Zone 1, Number 3, Yonghe Road,Shiyan town, Baoan District, Shenzhen, China.
Copyright © 2021 ZLPOWER Electronics Co., Ltd. | 粤ICP备13066161号