    • Commodity name: 1-3KVA IP65 Outdoor Online UPS
    • Commodity ID: 1037782259651665920

    RA series High frequency outdoor UPS is used In suburban district, remote road or mountain, severe environment such as areas with high temperature(50℃), severe dust, moisture, rain, mist erosion, poor grid power quality(voltage durative higher than 260V or less than 160V, Frequency abnormal change)

    RA series IP65 High frequency outdoor UPS is used In suburban district, remote road or mountain, severe environment such as areas with high temperature(50℃), severe dust, moisture, rain, mist erosion, poor grid power quality(voltage durative higher than 260V or less than 160V, Frequency abnormal change)

     

    Features:

    ♦Provides a pure uninterrupted AC sine wave power supply for the outdoor communication / network equipment.

    ♦The use of high temperature, anti cold, salt spray, anti-corrosion, anti dust, waterproof, lightning protection design.

    ♦Advanced MCU micro processor control Technology, ensure long life reliability.

    ♦Excellent Protection against over voltage, overload, over current, overcharge and so on.

    ♦Strong anti-jamming capacity, Lightning, surge, short-circuit, network/fax/modem surge protection. Input L and N lines reverse wiring detection.

    ♦DC start function, input RFC reuses function.

    ♦Humanized bypass output adjustable.

    ♦Available to work with generators.

    ♦RS232 intelligent communication monitoring.

    ♦AS-400 Dry contact and SNMP cars remote intelligent control.

     

    Key words:
    • Outdoor Online UPS High Frequency UPS
  • Model RA1KL RA2KL RA3KL
    Capacity VA/W 1000VA/800W 2000VA/1600W 3000VA/2400W
    Input Nominal Voltage 110/115/120VAC or 200/220/230/240VAC                                    200/208/220/230/240VAC
    Voltage Range 115~300VAC
    Power Factor ≥0.97
    Frequency Range 50Hz:46~54Hz; 60Hz:56~64Hz
    Output Voltage 110/120/220/230/240(1±2%)VAC
    Frequency

    50/60Hz (Adjustable);
    50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%)

    60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%)

    Wave Form Pure sine wave
    Power Factor 0.8
    Harmonic Distortion ≤3% THD (Linear load)
    ≤7% THD (Non-Linear load)
    Overload Capacity 110%~150%  maintain 30s then turn to bypass ourput;
    >150% maintain 300ms
    Current Crest Ratio 3:1
    Connections Terminal block
    Efficiency Battery Mode 83%
    AC Mode 85%
    Battery Type Sealed free maintenance lead acid battery
    Nominal DC voltage 36VDC 96VDC 96VDC
    Stansard Battery Cabinet 3*100AH 8*100AH 8*100AH
    Backup Time (Full Load)

    Depens on the capacity of internal battery bank

    (24AH,38AH,65AH,80AH and 100AH optional)

    Charge Current (Max) 6.0A 6.0A 6.0A
    Charge Voltage (VDC) 41.1V±0.2VDC 110V±0.6VDC 110V±0.6VDC
    Recharge Time Depends on the capacity of  internal battery bank
    Bypass Automatic Transfer On overload and UPS failure
    Before UPS Power-on YES
    Transfer Time   0 ms(from imain to battery and vice versa); Less than 4ms from inverter to bypass and vice versa
    indicators LCD Display UPS status, Battery capacity, loading, Fault code (LCD: I/P &O/P voltage&frequency, Battery voltage)
    Audible   Bypass, Battery mode, Battery low, Overload, Fault
    Communications Intelligent RS232 serial port Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC 
    SNMP (Optional) Remote control UPS through SNMP management and Internet
    USB (Optional) Windows family software and Mac OS
    Environmental Operating Temperature 0~40℃
    Operating Humidity 0~95% (No condensing)
    UPS dimension L*W*H (mm)(UPS main body) 482*380*88.4 482*448*88.4 482*448*88.4
    L*W*H (mm)(Cabinet) 638*507*775 612*525*1511 612*525*1511
    Weight(kg) Net Weight (No battery) 52.00 100.00 100.00