Custom 3-Phase IP65 Outdoor Industrial UPS Uninterruptible Power Supply Key Features: True IP65 Waterproof & Dustproof – No external cabinet needed; direct outdoor installation in rain, snow, dust, or high-humidity areas. 3-Phase Industrial Topology – 380V/400V/415V I/O, compatible with global industrial equipment. Wide Temperature Range – -25℃ to +55℃ (optional -40℃), with integrated heater + fan thermal management. Fully Customizable – Battery type (LiFePO₄/AGM), enclosure material (stainless steel / painted steel), communication ports (Modbus/SNMP/ dry contact), and I/O terminals. Outdoor-Ready Design – UV-resistant coating, pole or ground mounting, bottom cable entry. Typical Use Cases: Intelligent traffic (traffic lights, radar, ETC) Oil & gas remote sites Outdoor 4G/5G telecom base stations Ports & offshore platforms Solar + storage integration Why Cooperate: 10+ years in industrial power protection OEM/ODM with flexible MOQ CE, IEC, TUV, IP65 test reports available
OEM ODM Custom 3-Phase IP65 Outdoor Industrial UPS Uninterruptible Power Supply
Key Features:
True IP65 Waterproof & Dustproof – No external cabinet needed; direct outdoor installation in rain, snow, dust, or high-humidity areas.
3-Phase Industrial Topology – 380V/400V/415V I/O, compatible with global industrial equipment.
Wide Temperature Range – -25℃ to +55℃ (optional -40℃), with integrated heater + fan thermal management.
Fully Customizable – Battery type (LiFePO₄/AGM), enclosure material (stainless steel / painted steel), communication ports (Modbus/SNMP/ dry contact), and I/O terminals.
Outdoor-Ready Design – UV-resistant coating, pole or ground mounting, bottom cable entry.
Typical Use Cases:
Intelligent traffic (traffic lights, radar, ETC)
Oil & gas remote sites
Outdoor 4G/5G telecom base stations
Ports & offshore platforms
Solar + storage integration
Why Cooperate:
10+ years in industrial power protection
OEM/ODM with flexible MOQ
CE, IEC, TUV, IP65 test reports available

-
Model 10KVA
15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA Capacity 10KVA
15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA System parameters Relationship between output power factor cosφ and the load 0.5~0.8 inductive load 100% 0.8~1.0 inductive load 100~80% 1.0 linear Load 80% 0.8~1.0 capacitive load 80% 0.5~0.8 capacitive load 70% Computer load 80% Overall efficiency (normal mode) Load 100% 92% 50% load 90% Overall efficiency (economic model):100% load
98%Max. leakage current(mA) 100 Standby economy mode Standard function Mean time between failure(MTBF) 200,000hours Computer monitoring interface Standard configuration RS232, RS485 / MODBUS Operating temperature 0 ~ 40 °C Max relative humidity 95 % (non-condensing) Cooling Forced ventilation (fan speed varies with load and temperature) Maximum altitude Rated power at 1000m (Reduce by -1% for every 100 meters rise), maximum 4000m Noise dB 52 ~62 Protection class(EN 60529) IP20 Incoming and outgoing line method Incoming from bottom Safety standard Safety regulations:GB4943, EN 50091-1; EMC: GB7260.2,GB/T 17626.2~5EMC, EN 50091-2 Physical parameters Width (mm) 540 550 For reference only Depth * Height (mm) 657*1132 725*1290 Weight (Kg) 170
250
295
335190 200 210 260 380 430 Rectifier input Rated voltage 380/400/415VAC Three phase three wire Voltage range ± 15 % (± 25 % adjustable) Rated frequency 50 / 60 Hz ( Automatic identification) Rated frequency 45 ~ 65 Input power pre-charge function Yes, 0-100%, can be set in 10-300 seconds Input power factor cosφ: Up to 0.99 (with harmonic filter) Input current harmonic component(THD) Minimum<5% (with harmonic filter) Max. input current [A] 18 27 36 55 72 108 130 Model 10KVA
15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA Capacity 10KVA
15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA System parameters Relationship between output power factor cosφ and the load 0.5~0.8 inductive load 100% 0.8~1.0 inductive load 100~80% 1.0 linear Load 80% 0.8~1.0 capacitive load 80% 0.5~0.8 capacitive load 70% Computer load 80% Overall efficiency (normal mode) Load 100% 92% 50% load 90% Overall efficiency (economic model):100% load
98%Max. leakage current(mA) 100 Standby economy mode Standard function Mean time between failure(MTBF) 200,000hours Computer monitoring interface Standard configuration RS232, RS485 / MODBUS Operating temperature 0 ~ 40 °C Max relative humidity 95 % (non-condensing) Cooling Forced ventilation (fan speed varies with load and temperature) Maximum altitude Rated power at 1000m (Reduce by -1% for every 100 meters rise), maximum 4000m Noise dB 52 ~62 Protection class(EN 60529) IP20 Incoming and outgoing line method Incoming from bottom Safety standard Safety regulations:GB4943, EN 50091-1; EMC: GB7260.2,GB/T 17626.2~5EMC, EN 50091-2 Physical parameters Width (mm) 540 550 For reference only Depth * Height (mm) 657*1132 725*1290 Weight (Kg) 170
250
295
335190 200 210 260 380 430 Rectifier input Rated voltage 380/400/415VAC Three phase three wire Voltage range ± 15 % (± 25 % adjustable) Rated frequency 50 / 60 Hz ( Automatic identification) Rated frequency 45 ~ 65 Input power pre-charge function Yes, 0-100%, can be set in 10-300 seconds Input power factor cosφ: Up to 0.99 (with harmonic filter) Input current harmonic component(THD) Minimum<5% (with harmonic filter) Max. input current [A] 18 27 36 55 72 108 130 Rectifier output
Maintenance voltage (20°C)Battery type 1 and 2:V = (2.266 * el.) Vdc Battery type 3:V = (2.21 * el.) Vdc Battery type 0:The voltage value is between type 1 and 2, and the voltage value adjustment range V =(2.09~2.4) * el. [Vdc]
Charging Voltage (20°C)Battery type 1 and 2:V(% Recharging<95%)= (2.32 * el.) Vdc Battery type 3:V(% Recharging<95%)= (2.4 * el.) Vdc Battery type 0:The voltage value is between type 1 and 2, and the voltage value adjustment range V =(2.09~2.4) * el. [Vdc] Max. charging voltage (2.32 * el.) Vdc Charger output voltage stabilization accuracy 1% DC ripple voltage component ≤1% Battery Number of units (rated voltage) 174 units(348VDC)~240 units(480VDC) Charging current setting 0.1A x C10
Battery discharge termination voltageBattery 1, 2 and 3:No-load discharge current, Vmin=(1.81 * el.) [Vdc] Battery 1, 2 and 3:output current=Ah Capacity, Vmin=(1.65 * el.) [Vdc] Battery 1, 2 and 3:output current>Ah Capacity, Vmin=(1.60 * el.) [Vdc] Battery 0 type: Factory default values, Vmin=(1.67 * el.) [Vdc] Adjustment range Vmin =(1.57~1.88) * el. [Vdc] Single-phase inverter output Rated capacity [KVA] 10 20 30 40 50 60 80 Rated power [KW] 8 16 24 32 40 48 64 Rated voltage [V] 220/230VAC Rated current [A] 29 72 109 145 182 218 290 Phase voltage setting 200 ~ 244 V (control panel) Peak factor(peak/Irms) 3:1 Wave form Sine wave Voltage phase shift (degrees)
100% balanced load
± 1'Voltage phase shift (degrees)
100% unbalanced load
± 2'Phase voltage difference
100% balanced load
± 1 %Phase voltage difference
100% unbalanced load
± 3 %Total harmonic distortion(THDv)
100% linear Load
<2%Total harmonic distortion(THDv)
100% non-linear Load
<5%Steady voltage stability ± 1 % Transient voltage response ± 5 % within 10ms Rated frequency Same as input Frequency stability ± 0.5% when asynchronous; During synchronization, ± 2% (can be set to ± 1-5%, operated by the panel) Overload 600' / 10' / 1' (110/125/150% Rated current) Short circuit for 0.1 seconds 2 times input Rectifier output
Maintenance voltage (20°C)Battery type 1 and 2:V = (2.266 * el.) Vdc Battery type 3:V = (2.21 * el.) Vdc Battery type 0:The voltage value is between type 1 and 2, and the voltage value adjustment range V =(2.09~2.4) * el. [Vdc]
Charging Voltage (20°C)Battery type 1 and 2:V(% Recharging<95%)= (2.32 * el.) Vdc Battery type 3:V(% Recharging<95%)= (2.4 * el.) Vdc Battery type 0:The voltage value is between type 1 and 2, and the voltage value adjustment range V =(2.09~2.4) * el. [Vdc] Max. charging voltage (2.32 * el.) Vdc Charger output voltage stabilization accuracy 1% DC ripple voltage component ≤1% Battery Number of units (rated voltage) 174 units(348VDC)~240 units(480VDC) Charging current setting 0.1A x C10
Battery discharge termination voltageBattery 1, 2 and 3:No-load discharge current, Vmin=(1.81 * el.) [Vdc] Battery 1, 2 and 3:output current=Ah Capacity, Vmin=(1.65 * el.) [Vdc] Battery 1, 2 and 3:output current>Ah Capacity, Vmin=(1.60 * el.) [Vdc] Battery 0 type: Factory default values, Vmin=(1.67 * el.) [Vdc] Adjustment range Vmin =(1.57~1.88) * el. [Vdc] Single-phase inverter output Rated capacity [KVA] 10 20 30 40 50 60 80 Rated power [KW] 8 16 24 32 40 48 64 Rated voltage [V] 220/230VAC Rated current [A] 29 72 109 145 182 218 290 Phase voltage setting 200 ~ 244 V (control panel) Peak factor(peak/Irms) 3:1 Wave form Sine wave Voltage phase shift (degrees)
100% balanced load
± 1'Voltage phase shift (degrees)
100% unbalanced load
± 2'Phase voltage difference
100% balanced load
± 1 %Phase voltage difference
100% unbalanced load
± 3 %Total harmonic distortion(THDv)
100% linear Load
<2%Total harmonic distortion(THDv)
100% non-linear Load
<5%Steady voltage stability ± 1 % Transient voltage response ± 5 % within 10ms Rated frequency Same as input Frequency stability ± 0.5% when asynchronous; During synchronization, ± 2% (can be set to ± 1-5%, operated by the panel) Overload 600' / 10' / 1' (110/125/150% Rated current) Short circuit for 0.1 seconds 2 times input