PRODUCTS CENTER
DO GSIII Split phase Off-Grid Inverter 120/240V 4KW 5KW 6KW
Category:
DOProducts
DOSplit Phase Inverter
Product Description
Built-in low frequency transformer inverter 120/240Vac Split Phase output 24V 48VDC to 120/240V.
Integrated MPPT charge controller·
Optional WIFI/ GPRS remote monitoring·
Built-in pure copper low frequency transformer·
Configurable grid or solar input priority.
Support multiple power sources, such as PV, battery, diesel generator and utility.
3 times peak power ability.
Multi-customized modes for diverse scenarios.
Compatible with lithium, lead-acid and GEL batteries.
Support WiFi and GPRS communication for remote monitoring.
| Model Parameters | GSII4000 | GSII5000 | GSII6000 | |
Power |
Nominal Power | 4000W | 5000W | 6000W |
| Surge Rating | 12000W | 15000W | 18000W | |
| Maximum PV Array Power | 5000W | 5000W | 5000W | |
| AC Input | Input Voltage Waveform | Pure sine wave/ same as utility or generator input (bypass mode) |
||
| Nominal input Voltage | HOT1-HOT2: 240VAC | |||
| Low Line Disconnect | 180Vac±4%(Normal) or 140Vac±4%(Wide) | |||
| Low Line Re-connect | 190Vac±4%(Normal) or 150Vac±4%(Wide) | |||
| High Line Disconnect | 270Vac±4%(Normal) or 270Vac±4%(Wide) | |||
| High Line Re-connect | 260Vac±4%(Normal) or 260Vac±4%(Wide) | |||
| Max AC input Voltage | Max280V | |||
| Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | |||
| AC Output |
Output Voltage Waveform | Sine wave | ||
| Power Factor | 1.0 | |||
| Nominal Output Voltage (V) | 104-110-115-120/208-220-230-240VAC(optional) | |||
| HOT1-N: 120Vac ±10%rms; HOT2-N: 120Vac ±10%rms; HO1-HOT2: 240Vac ±10%rms |
||||
| output phase diifference | HOT1-N and HOT2-N is 180°; HOT1-N and HOT1-HOT2 is 0°; HOT2-N and HOT1-HOT2 is 180° |
|||
| Nominal Output Frequency (Hz) |
50Hz ± 1Hz, 60Hz ± 1Hz | |||
| AC Charger |
Nominal Charger Current |
20A/35A/50A/70A/90A(According to the inverter model) ; adjustable 5 stages charging current; |
||
| Over charge Protection | Bat.V≥31.0VDC for 24V battery, Bat.V≥62.0VDC for 48V battery ;beeps 0.5s every 1s & fault after 60s | |||
| Solar Charger |
Rated Charge Current | alternative 80A | ||
| PV Input Voltage range | 30VDC-140VDC for 24V Inverter, 60-240VDC for 48V Inverter | |||
| Max.PV open circuit array voltage |
150Vdc PV for 24V inverter, 250V PV for 48V inverter | |||
| Charger mode | MPPT | |||
| PV Low Voltage Re-connect |
PV≥Bat.V+3V | |||
| PV Low Voltage Disconnect |
PV≦Bat.V | |||
| Efficiency | ≥97% | |||
| Battery Voltage |
Battery type | Lithium/Lead-acid (LifePO battery communication CAN485,Battery awake function,Battery equivalent) | ||
| Nominal DC input Voltage | 24/48VDC | |||
| Low Battery Alarm | 21VDC±0.6VDC for 24VDC | |||
| 42VDC±1.2VDC for 48VDC | ||||
| Low DC input shut & down |
20VDC±0.6VDC for 24VDC | |||
| 40VDC±1.2VDC for 48VDC | ||||
| High DC input Alarm & Fault |
32VDC±0.6VDC for 24VDC | |||
| 64VDC±1.2VDC for 48VDC | ||||
| Efficiency | Efficiency(Battery Mode) | ≥87% | ||
| Efficiency (Line Mode) | >98% | |||
| Transfer Time |
AC tO DC | 20ms(max) | ||
| DC tO AC | 15ms(max) | |||
| System Parameter |
Over-Load Protection | 110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps 0.5s every 1s,and Fault after 20s |
||
| Output Short Circuit Protection |
YES | |||
| Surge Rating | 1:3(VA) | |||
| Protections | Low battery, over charging, over load, over temp | |||
| Indicators | LED+LCD Display | |||
| General Specifications |
Operating Temperature Range |
0℃~40℃ | ||
| Storage Temperature | ﹣15℃~60℃ | |||
| Operation humidity | 5% to 95%(non-condensing) | |||
| Audible Noise | 60dB max | |||
| cooling | Forced air, variable speed fan | |||
| Dimension(L*W*H) | 530*400*190mm | |||
| Net Weight(kg) | 30kg | 35.5kg | 39kg | |

Subscribe
Check the latest news of our company anytime and anywhere.
Contact ZLPOWER
1-2 Floor, Building E, Liyukeng Industrial Zone, Beihuan Road, Shangwu Community,Shiyan Street, Bao'an District, Shenzhen,Guangdong, China